Film Thickness

A correct paint- or coating thickness is an important parameter in the surface treatment industry. The performance of a coating system is based upon correct application of this system following the paint manufacturers specification sheet. Each layer from primer to topcoat and individual intermediate layers are exactly specified with a minimum and maximum coating thickness. Often both a dry and wet film thickness is specified.

Although the dry film is the leading parameter often the wet film is measured during application in order to give the operator an indication of the applied wet film thickness. Measuring wet film thickness during application identifies the need for immediate correction and adjustment by the applicator The relationship between dry and wet film thickness depends on the volume of solids in the coating. The applied wet film thickness depend on many variables such as the type of coating, application method (air pray, brush, roller, airless spray, electrostatic, tribo gun, etc.), equipment quality, operator, substrate material , the size and shape of the part etc.....
A correct paint- or coating thickness is an important parameter in the surface treatment industry. The performance of a coating system is based upon correct application of this system following the paint manufacturers specification sheet. Each layer from primer to topcoat and individual intermediate layers are exactly specified with a minimum and maximum coating thickness. Often both a dry and wet film thickness is specified.

Although the dry film is the leading parameter often the wet film is measured during application in order to give the operator an indication of the applied wet film thickness. Measuring wet film thickness during application identifies the need for immediate correction and adjustment by the applicator. The relationship between dry and wet film thickness depends on the volume of solids in the coating. The applied wet film thickness depends on many variables such as the type of coating, application method (air pray, brush, roller, airless spray, electrostatic, tribo gun, etc.), equipment quality, operator, substrate material, the size and shape of the part etc.. Incorrect coating thickness could lead to technical problems or excessive costs.

Too low dry film thickness can lead to:
  • Insufficient corrosion protection
  • Hiding power problems
  • Erosion
  • Grinning
  • Holidays
  • Rust Spotting
  • Undercutting
Too high film thickness causes problems like:
  • Extra material costs
  • Sagging (Sags), Runs
  • Alligatoring
  • Cracking
  • Mud Cracking
  • Tackiness
Multiple layer systems are often measured layer by layer. After cure of each layer a large number of measurements are made and stored so statistics of each following paint layer can be compared with the previous layer to define the thickness of each individual paint film. .

Techniques and systems
There are many different techniques and systems to measure coating thickness. The choice of coating thickness gauge type depends on type of application, substrate properties, budget and other requirements. The following type of instruments are common in today’s coating and surface treatment industry:

Magnetic Pull-off
Magnetic pull-off gages are suitable for ferrous metal substrates only and use a permanent magnet combined with a calibrated spring which is linked to a graduated scale. The magnetic force between the magnet and ferrous steel substrate pulls the two together. The coating thickness separating the two makes it easier to pull the magnet away. The more coating between magnet and steel the easier the pull. The actual coating thickness is determined by measuring this pull-off force. Testing with magnetic gages is sensitive to surface roughness, curvature, substrate thickness, and the make up of the metal alloy. Magnetic pull-off gages are rugged, simple, inexpensive, portable, and usually do not require any calibration adjustment. They are a good, low-cost alternative in situations where electronic gauges are not allowed due to explosion risk or when quality goals require only a few readings during production.

Eddy Current
Eddy current techniques are used to nondestructively measure the thickness of nonconductive coatings on nonferrous metal substrates. A coil of fine wire conducting a high-frequency alternating current (above 1 MHz) generates an alternating magnetic field at the surface of the instrument's probe. When the probe is near to a conductive surface, the alternating magnetic field will set up eddy currents on the surface. The characteristics of the substrate and the distance of the probe from the substrate (the coating/layer thickness) affect the level of the eddy currents. The eddy currents create their own opposing electromagnetic field that is sensed by the exciting coil or by a second, adjacent coil. Modern dry film thickness gauges often combine the magnetic induction and eddy current methods in one instrument. These instruments are basically suitable to measure each non-magnetic layer on a magnetic surface or each non-conductive layer on a conductive metal surface such a aluminum , copper, brass, stainless steel….

Magnetic and Electromagnetic Induction
These gauges are used to measure non-magnetic layers on magnetic (ferrous) surfaces. Magnetic induction instruments use a permanent magnet to generate a magnetic field. A magneto-resistor or Hall-effect generator is used to sense the magnetic flux density at a pole of the magnet. Electromagnetic induction instruments use an alternating magnetic field. A soft, ferromagnetic rod wound with a coil of fine wire is used to produce a magnetic field. A second coil of wire is used to detect changes in magnetic flux. These advanced electronic instruments measure the change in magnetic flux density at the surface of a magnetic probe as it comes close to a steel surface. The level of the flux density at the probe surface is directly related to the distance from the steel substrate. By measuring flux density the coating thickness or layer thickness can be determined.

Ultrasound or Ultrasonic
The ultrasonic pulse-echo technique is used to measure the thickness of coatings on nonmetal substrates (plastic, wood, concrete etc.) without damaging the coating. The probe of the instrument contains an ultrasonic transducer that sends a pulse through the coating. The pulse reflects back from the substrate to the transducer and is converted into a high frequency electrical signal. The echo waveform is digitized and analyzed to determine coating thickness. In some circumstances, individual layers in a multi-layer system can be measured.

PIG or Destructive measuring
This method is often used on reference panels or in forensic inspections with failing coating systems. With this system a precise incision is made with a special cutting tool perpendicular to the surface. An illuminated measuring microscope is used to measure the width of the cut. Depending on the type of cutting tool the width is multiplied with a factor which leads to the coating thickness. This system is ideal for those circumstances where electronic gauges cannot be used. The thickness of individual layers can be determined as well with this system.

Wet film thickness measuring
Wet-film is most often measured with a wet film comb or wheel. The wet-film comb is a flat precision plate with calibrated notches on the edge of each face. They are made of aluminum, plastic, or stainless steel. The gauges are placed squarely and firmly onto the surface to be measured immediately after coating application and then removed. The wet-film thickness lies between the highest notch that touched the coating and the next uncoated notch. Wet film thickness (WFT) combs measurements are neither accurate nor sensitive, but they are useful in determining approximate wet-film thickness in an early stage of application of coatings on articles where size and shape prohibit the use of more precise methods. A wet film thickness wheel is a high precision, accurate and easy to use instrument which consists of a set of three wheels. The central wheel is of a smaller diameter and is eccentric relative to the two outer wheels. The wheel is rolled through the wet coating and the interface of where the inner wheel starts touching the paint indicates the wet film thickness. Better wet film thickness wheels are equipped with roller bearings for smooth rolling and knurled outer wheels to allow measurements to be taken on slippery coatings or on fast moving substrates such as coil coating.

Air Ultrasound
An air-ultrasonic device can be used non-destructively / non-contact on uncured powder coatings on smooth metal surfaces to predict the thickness of the cured film before the powder coating is cured in the oven.
Standards News FAQ Links
Search on application | Film Thickness | Alle productgroepen

CALIBRATION STANDARDS FOR COATING THICKNESS GAUGES

Plastic foils and certified plastic shims. Available in the range of 12 to 20.000 micron. These foils can be applied to all ferrous- or non-ferrous metal substrates. Non-Certified Plastic Shims Non-Certified Plastic Shims (foils) ...

COATING THICKNESS CALIBRATION STANDARDS (CERTIFIED)

Coated metal calibration standards consisting of a set of 4 calibration plates with epoxy coating on steel or aluminium. Verify the accuracy and operation of coating thickness gauges. An important component in fulfilling both ISO/Q...

COATING THICKNESS GAUGE FOR ALL SUBSTRATES

The Defelsko Positector 200 measures non-destructively a wide variety of applications using proven ultrasound technology. Measures coating thickness over wood, concrete, plastics, composites and more. Advanced models measure up to 3...

COATING THICKNESS GAUGE POSITECTOR 6000

The TQC Coating Thickness Gauge Positector 6000 from Defelsko is a rugged, fully electronic coating thickness gauge that uses magnetic and eddy current principles to measure, accurately and quickly, coating thickness on both ferrous...

CROSS CUT ADHESION TEST KIT (MASTER PAINT PLATE)

The TQC Cross Cut Adhesion Test KIT (Master Paint Plate) is a stainless steel measuring tool that features: a 1 mm, 1.5 mm, 2 mm and 3 mm cross cut adhesion test according NEN-EN-ISO 2409:2003 and ASTM D 3359 (X-cut) Andreas cross. ...

DEFELSKO 6000 PROBES FERRO NON-FERRO

Strong, wear resistant, ruby-tipped probes. Ferrous & Non-Ferrous probes for measuring non-magnetic coatings on a Ferrous surface or non-conductive coatings on a Non-Ferrous surface. The different Fe/NFe probes are available i...

DEFELSKO 6000 PROBES MICRO FERRO NON-FERRO

Strong, wear resistant ruby tipped probes. Micro Ferrous & Non-Ferrous probes for measuring coatings on a Ferrous or Non-Ferrous surface. This small sized probes are specialy developed for measurments in small areas and pipe dia...

DIGITAL USB MICROSCOPE WITH LCD SCREEN

Small, portable, inexpensive and easy microscope with LCD display that can be connected directly to a PC. Supplied with software for immediate inspection and measuring. The unique optical design combines the advantages of a USB-micr...

FERRO NON-FERRO PROBES FOR QNIX 8500

Fe / NFe probes to measure non-ferromagnetic coatings on ferromagnetic substrate, for example measuring on steel- or iron-substrates and non-ferromagnetic and electrically non-conductive coatings (insulating coatings) on non-ferroma...

FERRO PROBES FOR QNIX 8500

Fe Probes to measure non-ferromagnetic coatings on ferromagnetic substrate, for example measuring on steel- or iron-substrates. QNix® 8500 sat - a world novelty The worldwide new, only thumb-size radio control probe allows safe...

FILM THICKNESS GAUGE FTG2000

The TQC Film thickness gauge is a high precision film and foil thickness gauge, especially developed for measuring so-called "replica tapes" as Testex®, used mainly to measure the surface profile. The large clear display makes ...

IDEAL FINISH ANALYSIS SOFTWARE

The TQC Ideal Finish Analysis Software is the most advanced coating climate, coating cure and coating thickness monitoring software package available today. With two user levels Ideal Finish Analysis offers user friendly reporting f...

MICRO PROBE 500µM FOR QNIX 8500

Magnetic-inductive measurement probe with a measuring range of 0-500 µm for the most precise measurements of non-ferromagnetic coatings especially within the lower measuring range. Designed to measure thin, non-ferromagnetic...

NON-FERRO PROBES FOR QNIX 8500

NFe Probe to measure non-ferromagnetic and electrically non-conductive coatings (insulating coatings) on non-ferromagnetic and electrically conductive substrate, for example measuring on aluminium-, zinc-, brass- and certain stainle...

PLASTIC WET FILM COMB

The TQC Wet Film Comb made of plastic, to measure wet film thickness between 25 and 900µm. The TQC Wet Film Comb is designed as a disposable thickness gauge. It can be kept as a record of wet film thickness measurement for ISO...

POSITECTOR SMARTLINK

PosiTector SmartLink and free mobile app turns your cell phone or tablet into a virtual PosiTector gauge. PosiTector SmartLink accepts all PosiTector 6000, RTR-H, and SPG probes easily converting to a coating thickness gage or surfa...

POSITEST MAGNETIC PULL-OFF THICKNESS GAUGE

PosiTest magentic pull-off thickness gage for the non-destructive measurement of non-magnetic coatings (paint, enamel, galvanizing, metalizing, plating, etc.) on steel.

POWDER COATING METER POWDERCHECKER XP

The TQC PowderChecker XP optimizes the powder application by measuring the output of the cabin. The TQC PowderChecker XP measures uncured powder coatings using ultrasonic technology to automatically calculate a predicted cured thic...

PowderTAG Thickness Analysing Gauge

PowderTAG measures powder coating thickness before and after cure, non-contact and non-destructive. A sophisticated combination of specific powder-, infrared- and photo-thermal techniques measures the thickness of powder coatings in...

QNIX 4200 COATING THICKNESS GAUGE FERRO

Handy and robust coating thickness gauge. QNix® 4200 was developed particularly for measuring tasks in the automobile industries. This compact gauge permits extremely precise measurements of lacquer and corrosion protection thic...

QNIX 4500 COATING THICKNESS GAUGE FERRO NON-FERRO

QNix® 4500 - a handy, fast and robust coating thickness gauge. QNix® 4500 was developed particularly for measuring tasks in the automobile industries. This compact gauge permits extremely precise measurements of lacquer and ...

QNIX 8500 COATING THICKNESS GAUGE FERRO NON-FERRO

QNix® 8500: A modular precision measuring system for maximum flexibility. In close collaboration with practitioners from the handwork, industry and service sectors a new generation of a modular measuring system resulted that bel...

Super PIG III destructive Paint Inspection Gauge

The TQC SP1100 SuperPIG is a destructive precision tool for inspection and thickness measurement on single or multiple coats on virtually all substrates, including wood, plastics, metals etc. Also observes and measures substrate and...

The Paint Inspector s Field Guide

The Inspection of protective coating systems for corrosion control includes a wide range of test methods and techniques. In the Paint Inspector’s Field Guide( PIFG ) a wide range of these inspection methods are covered in an e...

TQC FE|NFE COATING THICKNESS GAUGE

This handy, robust and easy to use TQC coating thickness gauge is ideal for measurement tasks in various industries and paint applications. This compact meter allows measurement of painted objects, or other corrosion protective laye...

USB measuring microscope - Model 2012

Small, portable, inexpensive and easy microscope that can be connected directly to a PC. Supplied with software for immediate inspection and measuring. The unique optical design combines the advantages of a USB-microscope digital ...

WET FILM MEASURING COMB

Rectangular promotion measuring comb with a range of 25 to 2032 µm. Made of top-quality, weather-resistant aluminum. Special printing possible with larger orders.

WET FILM THICKNESS GAUGE STAINLESS STEEL

The TQC Wet Film Thickness Gauge WG is a hexagonal/octagonal precision measuring comb made of heavy stainless steel. The high-grade stainless steel will not be affected by acid or base elements. Models available for several differen...

WET FILM THICKNESS WHEEL

Specially by TQC developed instrument for use on wet lacquers, paint and coil coated surfaces. Equipped with a precision roller-bearing for smooth rolling over the surface . The wheel has three rims, the inner rim being eccentric to...