Temperature, humidity and related climatic parameters are important to many industrial processes and the application of paint and coatings is no exception to that rule. Measuring and controlling of climatic parameters such as relative humidity, air-temperature, dewpoint and moisture is vital to a successful application of high-end coating systems. Incorrect climatic conditions during pre-treatment and application often lead to premature failing coatings systems....

Temperature, humidity and related climatic parameters are important to many industrial processes and the application of paint and coatings is no exception to that rule. Measuring and controlling climatic parameters such as relative humidity, air-temperature, dewpoint and moisture is vital to a successful application of high-end coating systems. Incorrect climatic conditions during pre-treatment and application often lead to premature failing of coatings systems.

Temperature and relative humidity during application
Almost each coating has its own requirements regarding climatic conditions.
Most two component epoxies require a relatively high temperature (often more than 15°C) combined with a low relative humidity. Moisture curing coatings need a high humidity level in order to cure. Water based coatings cannot be applied at very low temperatures and too low humidity causes the paint to dry too fast while a high humidity slows the curing process down. Surface tolerant coatings accept a wider range of climatic conditions and some coatings can even be applied underwater.

Each paint manufacturer will mention in its application guidelines or MDS (material datasheet) specifically what type of climatic conditions are required. Wrong environmental conditions can lead to problems and defect such as:

  • Blistering
  • Bloom
  • Cheesiness
  • Cissing
  • Cratering
  • Crowsfooting
  • Dryspray
  • Tackiness
  • Solvent Popping
  • Solvent detention
For explanations and extensive information about paint defects check the "Fitz Atlas of Coating Defects".

DewPoint
A special parameter which is of high importance in the coating industry is DewPoint. Wikipedia describes Dewpoint as " The dew point is the temperature to which a given parcel of humid air must be cooled, at constant barometric pressure, for water vapour to condense into water. The condensed water is called dew. The dew point is a saturation temperature.

The dew point is associated with relative humidity. A high relative humidity indicates that the dew point is closer to the current air temperature. Relative humidity of 100% indicates the dew point is equal to the current temperature and the air is maximally saturated with water. When the dew point remains constant and temperature increases, relative humidity will decrease."

In the surface treatment dewpoint is one of the most critical climatic parameters. Dewpoint always has to be observed in combination with the surface temperature. A surface temperature that is below the dewpoint temperature of its surrounding air will immediately show condensation. On a rough, blast cleaned surface, the small water drops of dew are hardly visible. However when this moisture is trapped under a paint film severe problems will arise over time. Corrosion under the paint, poor adhesion of insufficient curing are some of the possibilities.

Since the dewpoint temperature (Td) depends on the relative humidity (RH) and air temperature (Ta) it is quite unstable. Also the surface temperature may vary. This is why most paint manufacturers specify a Delta T (difference between Surface temperature and Dewpoint) of +3°C (+5°F).

Picture for example the complex micro climate inside a ballast tank of a ship that carries a warm cargo (eg. crude oil), sailing in a cold sea in humid air. One wall of the tank might be degrees above dewpoint while the other could be well below.

Dewpoint under 0°C is not possible. As soon as that temperature is reached we speak about a "Frost Point".

When should you measure the climatic conditions?

Basically the conditions should be observed prior to the pre treatment process until the coating reached a full cure. When the surface temperature of steel is below dewpoint temperature the bare steel will corrode instantly after blast cleaning.

Temperature of the coating or substrate
The coating temperature is important during application but also during storage. Most coatings will loose their performance once they have been frozen before/during their shelf life. Viscosity of paint is in direct relationship with the temperature of the paint which affects the application.

Extreme substrate temperatures also cause their share of problems. High substrate temperatures may cause the paint to dry too fast which could lead to pinholes or pores for example. Low surface temperature may prevent the paint to form a film as many coatings know a so called "Minimum Film Forming Temperature" or "MFFT" value.

Moisture in substrate
The moisture content of substrates to be coated is a critical factor as well. Fresh moist concrete will not hold any paint or applying a powder coating to a damp wooden panel will cause steam to be created when the panel passes through the curing oven, thus causing damage to the coating.

Check theMOISTURE section for more information and products about this topic.

Standards News FAQ Links

BASIC INSPECTION KIT

To fulfill the demand of many companies in the line of paint and their customers we composed the “Basic Inspection Kit”. In the field the need had arisen of one standard measuring set to perform all measurements and test...

CURVEX 3 BASIC DATALOGGER

The CurveX 3 Basic is an oven recorder designed for everyday use in powder coating lines. It’s a 4-channel temperature datalogger built in a sturdy machined aluminium case that fulfils the basic needs for quality control in p...

CURVEX 3 STANDARD OVEN LOGGER KIT

Profiling an industrial powder coating oven starts right here with the CurveX 3 Standard Oven Logger KIT. It contains all necessary items, just add the desired magnetic or clamp-type probes to make the oven logger KIT complete. The...

DEWCHECK 4 DOCKING STATION

For optimal use of the datalogging facilities of the instrument the TQC DewCheck 4 Docking Station is available. The Docking Station is provided with 3 strong Neodymium magnets which hold instrument and dock firmly against ferrous s...

DEWCHECK 4 SERIES 2 - DEWPOINT METER

The TQC DewCheck 4 - Dewpoint Meter (DPM)/ Dewmeter is an extremely versatile dewpoint meter to measure and record all climate parameters required to treat surfaces. This easy to use and robust dewmeter conforms to ISO 8502-4 & ...

DEWMAG MAGNETIC THERMO - HYGROMETER

Dewmag Magnetic Thermo - Hygrometer , for use during application of protective coatings. Thermo-hygrometer containing a combination of a precision hygrometer and two bimetal-thermometers. The relative humidity and temperature scale...

DEWPOINT CALCULATOR

The TQC Dewpoint calculator is a handy tool to determine dewpoint temperature based upon the measurements from the sling psychrometer. Includes a Celsius / Fahrenheit converter.

DIGITAL ANEMOMETER

Digital wheel anemometer with a built-in thermometer for measuring air velocity in for example ventilation ducts, air conditioning, etc. The meter has a 'Hold' function for holding the measured values.

DIGITAL THERMO HYGROMETER

Digital thermo hygrometer for indoor use, to be used as benchtop or wall model. Very large display (56 x 40 mm.), readable up to a distance of approximately 10 mtr. Memory for minimum and maximum values and humidity readings, tog...

ELECTRONIC DATALOGGER SATO SK-L200TH II

Extremely compact datalogger for recording temperature and air humidity. Complete with attached combiprobe (T/RV). A wire-combiprobe is optional. Directly programmable from the keypad or PC. Complete with attached combiprobe, USB ca...

ELPRO ECOLOG TEMPERATURE & HUMIDITY DATALOGGER

An extensive series superior quality Swiss dataloggers. Depending on the model temperature and/or humidity can be measured and logged. The real time and stored measured values can be read directly from the integrated display. All lo...

ELPROLOG SOFTWARE

This software is the basis program for the dataloggers from the ECOLOG, HOTDOG and HOTBOX series. This comprehensive programme offers a range of options such as: graphs, zoom function, zoom in zoom, tables, multi-curve, bar charts (...

HAIR HYGRO THERMOMETER

High precision industrial hair-hygrometer. Designed to be attached to a facade. Casing made of nickel-plated SPCC. Diameter 150mm. Measuring range RH: 20 to 100% Measuring range temperature: -10 to 50°C

Hotwire-Anemometer

The TQC Hotwire-Anemometer is ideal for low air velocity and volume measurement. The TQC Hotwire Anemometer measures the air velocity in m/s, km/hr, ft/min, MPH and Knots.The instrument is supplied with a built-in temperature probe ...

IDEAL FINISH ANALYSIS SOFTWARE

The TQC Ideal Finish Analysis Software is the most advanced coating climate, coating cure and coating thickness monitoring software package available today. With two user levels Ideal Finish Analysis offers user friendly reporting f...

INFRARED THERMOMETER PROFESSIONAL

The TQC Infrared Thermometer Professional is designed to measure surface temperature under harsh industrial circumstances without the need of making contact with the object. The high quality optics (distance to spot size 50:1) makes...

MAGNETIC THERMOMETER FOR SURFACE TEMPERATURE

The TQC Magnetic Thermometer measures surface temperature. The thermometer can easily be placed on ferrous substrates with the strong magnet on the back. Surface temperature can be read out in both °C and °F. Measuring Range...

PRECISION THERMOMETER

The TQC Precision Thermometer is a handy pocketsize thermometer with foldable stainless steel probe. Suitable for measurements in liquids and semisolids. Large clear display, ergonomic design and easy to clean. The instrument is equ...

SLING PSYCHROMETER

Bacharach type sling Psychrometer for indicating percent relative humidity on the basis of the wet bulb-dry bulb thermometer principle. The plastic case of the instrument is equipped with conversion scale for calculating the percent...

THERMAL IMAGING CAMERA FLIR

FLIR thermal imaging cameras give a temperature picture of any object. Each temperature has its own color temperature that is easy to read out with the help of the temperature scale that is always in view. Low temperatures have dark...

THERMO-HYGROMETER

The TQC Thermo hygrometer is a simple hand-held digital thermo/hygrometer. Temperature and air humidity are displayed simultaneously. Equipped with MIN/MAX memory, °C/°F selection, HOLD function and dewpoint indication. Th...

USB DATA LOGGER FOR TEMPERATURE AND RH

USB data logger for temperature and relative humidity. The USB data logger has a memory for 32.000 readings (16000 temperature- and 16000 humidity readings), a dewpoint indication, a user-selectable alarm. The measuring interval can...