MFFT-MINIMUM FILM FORMING TEMPERATURE BAR

More Photos

vf9600_2web.jpg vf9600_1web.jpg

1-temperature.png

MFFT-MINIMUM FILM FORMING TEMPERATURE BAR

Temperature gradient plate for determining minimum film forming temperature test.
The minimum film forming temperature is the lowest temperature at which an emulsion, latex or adhesive will uniformly coalesce when applied on a substrate as a thin film.
Knowing the MFFT temperature allows formulators to create a product that cures correctly under the required application conditions. The instrument can also be used to define the white point/glass transition temperature of dispersion materials, synthetic resins, enamels etc. and the blocking power and stacking capability of coated papers, foils, prints...
TQC MFFT TTEST is a sophisticated test instrument with a ground hard-chrome plated metal platen as to deposit the specimen. By heating and cooling the platen any variable temperature gradient within the range of -30 to +250 °C can be produced and kept constant for any given period. The platen is equipped with 10 or 20 evenly spread temperature sensors. The temperature is controlled through an integrated digital controller with a digital display and measuring-point selector that covers the whole range.To define the MFFT the specimen is applied on the platen with a film-applicator and protected from ambient conditions through a transparent cover in which a flow of dried air is created to prevent condensation and to assure repeatability. To determine the blocking power the specimens on the platen are weighed by defined loads to simulate the stacking capability.The TQC MFFT TEST meets the following standards: acc. to current standards: DIN ISO 2115 – DIN 53366 – ASTM D 2354 – ASTM D 1465 – ISO 2115 – ISO/DIS 4622

VF9600
TQC MFFT 10 -10...+80°C
10 built-in temperature sensors
Temperature gradient: max. 20 K (depends on the external cryostat)
Hinged transparent cover made of PMMA, max. working temperature 80°C

VF9700
TQC MFFT 20 -30...+250°C
20 built-in temperature sensors
temperature gradient: max. 100 K (depends on the external cryostat)
Hinged transparent cover made of PMMA, for temperatures up to +80°C
Hinged transparent cover made of stainless steel and safety glass for temperatures up to +250°C.

1/1
1/1
Datasheet Request Quotation Links
User Manual Faqs References
Brochure Xtra Info Software
Accessories Terms of Delivery Standards
Video